This eddy current testing system automatically detects longitudinal harmful flaw on the zone of approx. 300 mm from both end of steel pipe, where used be dead zone for inspection, while pipe is turning. If a harmful flaw is detected on a pipe end, NG marking is done on the designated position of the pipe. This system is also applicable for inspection of round steel billet, round bar and nonferrous materials.
If you need further information or have question → CONTACT US
| Main Specification | |
|---|---|
| Material to be inspected | Carbon steel, Alloy steel, Stainless steel and Nonmagnetic metals |
| Outer diameter of pipe | Min. diameter 50 mm |
| Material condition | Metal structure and magnetic property shall be uniform |
| Peripheral velocity | 60 m/min. (constant) |
| Probe | Theta probe |
| Flaw | Longitudinal , linear shape |
| Detecting accuracy | Min. 0.3 mm depth x 0.5 mm width x 25 mm length artificial flaw (S/N : more than 5) |
| Electric power | AC 200 V ±10%, 3-phase, approx. 5 KVA |
| Air | 0.4 MPa, more than 1 m3/min. (dry) Normal consumption : approx. 0.8 m3/min. |
| Grounding | C-type (less than 10 ohm) |
※ Click photograph to view movie of ECT System for Steel Pipe End (Type L)